Trane converts unitary products from R-22 to R-410A ahead of schedule

Trane, a business of Ingersoll Rand, completed a global conversion effort from hydrochlorofluorocarbons (HCFC) R-22 to the non-ozone-depleting hydrofluorocarbons (HFC) refrigerant, R-410A, for its entire unitary product line in the Americas. Trane accomplished this to ensure full compliance with federal U.

11/01/2009


Trane, a business of Ingersoll Rand, completed a global conversion effort from hydrochlorofluorocarbons (HCFC) R-22 to the non-ozone-depleting hydrofluorocarbons (HFC) refrigerant, R-410A, for its entire unitary product line in the Americas. Trane accomplished this to ensure full compliance with federal U.S. Clean Air Act provisions implementing the Montreal Protocol's phaseout of HCFCs. Unitary products are packaged products that are designed, built, and tested in manufacturing facilities, then delivered to the customer for quick installation and operation. The Clean Air Act has mandated that no new R-22 products can be shipped after Dec. 31, 2009.

 

Trane made the announcement at a celebration and Town Hall meeting at the company's plant in Clarkesville, Tenn. At a press briefing held before the Town Hall meeting, Jeff Moe, Director—Global Regulatory Planning & Conformance, Ingersoll Rand, said that Trane was faced with “the most significant regulatory impact the HVAC industry has faced. In the U.S., total conversion away from R-22 use in new equipment must occur by Jan. 1, 2010. At the same time, [mandatory] increased minimum efficiency requirements for commercial unitary are driving additional product change.”

 

Rather than work on the converging refrigerant and efficiency requirements in series, Trane addressed both of them in parallel by redesigning and reengineering all commercial unitary products and some chiller products over a 3-year period. In the end, not only are these products using non-ozone-depleting refrigerants, they are said to have improved efficiency, reliability, serviceability, manufacturability, and safety.

 

The following statistics underscore the size and significance of Trane's achievement:

 

  • $100 million was invested in new manufacturing systems and equipment in facilities that manufacture these new products in the Americas.

  • Research, testing, and development costs totaled more than $11 million.

  • More than 500 employees from the U.S., China, and France worked more than 3 million hours on the design and engineering side alone.

  • The conversion project was completed on time.

 

As part of this reengineering and redesign effort, Commercial Systems launched 17 new products over the past 18 months. According to Trane, this represents more new products than the company has introduced over the past 20 years.

 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me