Touch-safe ring lug terminal blocks

The ST Ring Lug Terminal Block Series has been expanded with three touch-safe terminals, the ST5 N, ST6 and ST25.

11/27/2011


Touch-safe ring lug terminal blocks. Courtesy: WeidmullerWeidmuller expanded their ST Ring Lug Terminal Block Series with three touch-safe terminals, the ST5 N, ST6 and ST25. Featuring a slimmer profile, a hinged shroud, and a self-locking (captive) fastener this new design offers the fastest termination method for ring lug style terminals.

Although suitable for standard wire termination applications in the power generation, semi-conductor manufacturing, and transportation industries, Weidmuller’s new ST Series modules are ideal for use in current transformer applications where the operator risks potential exposure to high voltages. Also included in the ST Series expansion are new variations of Weidmuller’s classic open-style ring lug terminals.

Weidmuller’s ST Series modules feature the same touch-safe design with an optional integrated test socket screw head, which allows the user to insert a current meter without circuit disruption. The most unique, ST6 feed-through terminal is offered with a companion slide link disconnect terminal, the ST6 T. Used together, they can be configured to create multiple phase testing blocks for current transformer applications. The operator can install a meter into the test socket screw head of the ST6 T and open the circuit via the slide link disconnect, allowing the current to flow through the meter. When testing is complete, the slide link disconnect can be moved to the closed position and the meter can be removed.

Weidmuller’s ST Ring Lug Terminal series meets CSA/UL standards for high voltage power transmission applications with ratings up to 1000V and 100A and wire gauges from 26 to 3AWG. The new ST Series modules also include a jumper/bridging channel to distribute voltage and signals, a combi-foot design for TS-32 and TS-35 DIN-rail mounting, and numerous connection options from lug dimension to standard or integrated test socket screws. All terminals in the line accept Weidmuller’s Dekafix (DEK) and WS markers and are offered with additional accessories such as adapter sleeve/pins, jumpers for cross-connection, and end plates.

Weidmuller

www.weidmuller.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me