Torque transducers also measure speed

The T40B and T40FM torque transducers by HBM are able to measure torque and speed at the same time in harsh conditions.

08/01/2013


The T40B and T40FM torque transducers by HBM are able to measure torque and speed at the same time in harsh conditions. Courtesy: HBMHBM's T40B and T40FM torque transducers include an integrated speed measurement system and are specifically designed to work in harsh environments such as those that contain humidity, condensation, dust, oil and grease. The T40B and T40FM takes measurements based on the contactless sensing of an anisotropic magnetoresistive (AMR) sensor. The transducer integrates both the magnetic technology and the speed measurement sensor, which saves space and makes installation easier.

The T40's optional speed measurement sensor lets the device measure both torque and speed (rpm) at the same time. The T40 torque transducer measures speed with a 1024 pulse output, which provides users a far higher resolution than traditional optical systems.

In addition, because the radial or axial distance between the sensor and the magnetic ring is only 2.5-mm, the rotational speed measuring system has a high tolerance of application-related vibrations.

An optional reference pulse signal is generated by a separate sensor that senses the corresponding magnetic field in the axial direction. The system can thus provide the signals to integrate the rotational speed and the angle of rotation in the control loop of downstream equipment such as a data acquisition system (DAQ).

Other features of the T40B and T40FM include:

  • Torque measuring ranges of up to 80,000 Newton-meters
  • Low measurement uncertainty
  • Good temperature stability
  • Up to 0.03% of full scale linearity and hysteresis combined
  • Standard response times of 1000, 3000, 6000 and 10,000 Hz options

HBM, Inc.

www.hbm.com 

- See more Control Engineering discrete manufacturing products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me