Top Tips for Daylighting Control

The term "daylighting" often appears in the pages of this magazine, but perhaps without a clearly defined notion of the engineer's role in such illumination schemes. According to daylighting expert Dr. Pekka Hakkarainen, director of technology and business development with Coopersburg, Pa.-based Lutron Electronics Co.

03/01/2005


The term "daylighting" often appears in the pages of this magazine, but perhaps without a clearly defined notion of the engineer's role in such illumination schemes.

According to daylighting expert Dr. Pekka Hakkarainen, director of technology and business development with Coopersburg, Pa.-based Lutron Electronics Co., the definition we're really talking about, as far as consulting engineers are concerned, is the ability to adapt electric lighting in the presense of daylight.

Hakkarainen, who recently spoke before the Emerging Technologies in Energy Efficiency Summit in California, explains the basic components of a typical daylighting system consist of smart ballasts and sensors, including photocells, infrared receivers, occupant sensors and wall-station controls, and finally the control device itself, which runs the algorithm. In a nutshell, he says, such a smart lighting control system should collect data from these interconnected sensors, but then interpret this information and transmit that information to other ballasts to adjust light levels accordingly.

Hakkarainen offers this advice:

  1. Be aware of systems that use exterior vs. interior sensors. The latter, he argues, require lower maintenance and offer better local response.

  2. Understand the operating principles of sensors—how they work; what kind of features they offer; whether they're good; and most importantly, where to put them. "If a sensor is properly placed, the illumination corresponds with the task. If more light shines on the sensor, the less electric light required," said Hakkarainen.

  3. Optional, but often useful, is an understanding of the algorithm schemes used in the control devices.

According to Hakkarainen's colleague, David Bennett, manager of commercial marketing, the need to control electric light in the presence of daylight will only continue to grow for three major reasons:

  1. LEED

  2. Emerging energy codes

  3. An emphasis from owners to make spaces more comfortable.

The good news, adds Hakkarainen, is that current technology, particularly regarding addressable ballasts, accommodate an expansion of daylighting control, even if it's not part of the initial scheme.

"I really think the pairing of daylighting and addressable ballasts will have the biggest impact on the design community," he says.

Bennett adds system control flexibility is key, as a switching system for even greater control, such as time-clock management, or occupancy schedules, can also be easily and reasonably added.

"Our approach is to go on a fixture-by-fixture or room-by-room basis. This way if you can identify the human comfort level, it's easy to adapt the lighting control," says Bennett.

For a white paper on electric lighting control and daylighting visit the Lighting community at www.csemag.com .





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me