Tips to design multifamily and mixed-use buildings: Electrical, lighting

Multifamily dwellings and mixed-use buildings are becoming more prevalent. Some best practices and tips are offered for engineering electrical, power, and lighting systems in these residential buildings.

07/26/2017


Respondents

Respondents:

  • Brian Berg, PE, LEED AP, CEM, Associate Principal, Glumac, Irvine, Calif.
  • David Crutchfield, PE, Principal, RMF Engineering, Charleston, S.C.
  • Kieran Healy, PE, Mechanical Engineer, CCJM, Chicago
  • Lui Tai, PE, Technical Services Director, JENSEN HUGHES, Toronto
  • Robert J. Voth, Executive Vice President, Bala Consulting Engineers, King of Prussia, Pa.

CSE: Describe a recent electrical/power system challenge you encountered when working on such a project.Top 3 lights, lighting products used in engineered multidwelling/retail complexes/restaurants LEDs	95% Lighting controls, addressable systems	73% T5, T8, or T12 (any size)	59% Courtesy: Consulting-Specifying Engineer 2017 Lighting and Lighting Controls Study

Berg: Dealing with utility companies for submetering is always a challenge. Some utilities allow submetering of all residential units while other utilities require utility meters for each residential unit. This greatly impacts spatial requirements and billing methodology. These conversations need to occur and be documented with the utility at the very beginning of the project.

CSE: Describe a recent standby, emergency, or backup power system you designed, and its challenges and solutions.

Berg: An owner recently had us locate an emergency generator on a median in the middle of the street underneath an elevated train track. Coordination needed to occur between the utility engineers, the city engineers, and the train engineers (pun intended) to allow this to happen and to navigate the infrastructure from the generator, across a city street, and to the building.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
January/February 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me