Tiny linear servomotor is piezo application replacement

Nippon Pulse America's Linear Shaft Motor, which is 4 mm in diameter, is reportedly designed to be a replacement in piezo-type applications.

08/23/2011


Nippon Pulse America introduced its smallest linear servomotor, the 4 mm Linear Shaft Motor. The 4mm shaft diameter, a small forcer size (10 mm x 10 mm), a total weight of 9 grams, and strokes as long as 40 mm make the 4 mm Linear Shaft Motor a suitable replacement in piezo-type applications. 

The 4 mm Linear Shaft Motor is reportedly quiet due to the absence of friction since the only mechanical contact section is the linear guide. The coreless construction of the Linear Shaft Motor totally eliminates cogging.

The Linear Shaft Motor's high motor stiffness allows it to be used in high precision positioning applications where a resolution of 0.09 nanometers is achievable. With the Linear Shaft Motor, you will find that you have virtually no fluctuation in speed.

Durable construction makes it possible to operate the Linear Shaft Motor in harsh conditions, including a vacuum situation and underwater.

Compared to other linear motors on the market, the Linear Shaft Motor is compact and lightweight. Due to its design, the Linear Shaft Motor has no backlash.

Specifications for S040D Linear Shaft Motor:

  • Continuous stall thrust - 0.5 N
  • Continuous stall current - 0.4 A
  • Peak thrust 2 N
  • Peak current - 1.8 A
  • Shaft diameter (D) 4 mm (0.16 in.)
  • Slider length (A) 25 mm (0.9 in.)
  • Slider width (B) 10 mm (0.39in.)
  • Mounting pitch (P x P1) 21.5 x 4 mm
  • Mounting screw (M x l) 4-M2
  • Gap 0.5mm (0.02 in.)
  • Slider weight 0.01 kg/F
  • Available stroke 20, 30 & 40 mm
  • Magnetic pitch (N-S) 9 mm (0.354 in.) (N-S)

www.nipponpulse.com 

Nippon Pulse America

- Edited by Chris Vavra, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me