Timer relay module

The 859 Series DIN-rail Timer Relay Module from Wago has On-/Off-Delay timer modes and multiple time ranges for switch and package de-bounce sensors.

12/09/2011


The 859 Series DIN-rail Timer Relay Module has On-/Off-Delay timer modes and multiple time ranges for switch and package de-bounce sensors. Courtesy: WAGOWago Corp.’s 859 Series DIN-rail Timer Relay Module offers On-/Off-Delay timer modes and multiple time ranges for diverse applications such as switch and package “de-bounce” sensors. Unlike traditional designs, the 6 mm 859 Series carries a top-mounted potentiometer for fine-tuning delay time without removing unit from DIN-rail. On-Delay mode can prevent simultaneous excess inrush currents by delaying machine startup. Off-Delay mode can enable auxiliary components, such as fans, to continue operation after machine shutdown.

The 859 Series is available with Electromechanical (SPDT) or Solid State Relay (SPST-N.O.) outputs. Selectable via two DIP switches, 859 Series provides four standard time delay ranges from 0.2 seconds to 10 minutes. Optional time delay ranges of 2.0 seconds to 35 minutes are also available. 859 Series input voltage ranges from 19.2–28.8 V dc; outputs are 6A/24 V dc (electromechanical) and 2A/24 V dc (Solid State).

www.wago.us

Wago Corporation

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me