Time delay fuse

FUSETRON 250 V FRN-R and 600 V RFS-R energy-efficient, dual-element, time-delay fuses are manufactured by Cooper Bussmann and allow for closer sizing to load with smaller fuse amp ratings than non-time-delay fuses on most motor and transformer primary applications.

04/13/2012


FUSETRON 250 V FRN-R and 600 V RFS-RFUSETRON 250 V FRN-R and 600 V RFS-R energy-efficient, dual-element, time-delay fuses are manufactured by Cooper Bussmann and allow for closer sizing to load with smaller fuse amp ratings than non-time-delay fuses on most motor and transformer primary applications. These fuses fit any class K5 or H fuse blocks and holders, and with a 2:1 selective coordination amp ration, they prevent overcurrent events from opening upstream fuses. Features include a 200 kA interrupting rating for protection against fault currents, and insulated end caps to reduce exposure to live parts and to extend air gap distance between blades of adjacent mounted fuses or to housing.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me