Three-phase monitoring relay

Carlo Gavazzi's DPD Series 3-phase voltage and frequency monitoring relay provides the flexibility in compact dimensions and protection against phase reversal.

03/22/2017


Carlo Gavazzi's DPD Series 3-phase voltage and frequency monitoring relay provides the flexibility in compact dimensions and protection against phase reversal.This DPD Series 3-phase voltage and frequency monitoring relay provides protection against phase reversal, phase loss and if the phase asymmetry, voltage or frequency measurements are not within the user-configured settings and/or thresholds. The DPD Series settings can easily be modified through an Android App via a smartphone/tablet or via a USB NFC reader/writer connected to a computer. Under and over threshold settings can be set, as well as hysteresis and time delays. They are uploaded into the DPD Series by means of its NFC configuration. Neither potentiometer settings nor DIP switches are used for the device set-up, and after it is set-up, it can be password protected, to ensure safety while in use.The main advantage of the DPD Series is its high versatility and multifunction design. The set-up can be changed at any time and can be replicated, and stored on as many devices as needed. The set-points are extremely precise as they are digital, and much more accurate than they would be with potentiometer settings.

Carlo Gavazzi

www.gavazzionline.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me