Three keys to successful energy recovery

Consider these energy recovery options for a nonresidential building.

08/29/2014


 

 

When evaluating energy recovery options for a facility, there are three key items to consider:

 

1. Understand the systems and internal processes of the existing facility or design intent. Take these processes to the model and develop a unique load profile for the facility.

2. Overlay the other HVAC systems in the load profile and find opportunities where energy can be shared. Also, review the processes to see what other forms of recoverable energy are available and try to pair them with the technologies that are available.

3. Understand the utility rate structure the customer is under so the return on investment embraces what the customer is paying for, as some of these technologies can help with peak shaving versus energy reduction. This can have more of a significant impact than just energy reduction, which is why the heating and cooling load profile is so important, both annually and on a 24-hour/day basis.


Daniel Cohen is a senior associate and mechanical engineer with Environmental Systems Design. He specializes in high-efficiency buildings, central plants, and analysis and building modeling. Jay F. Ramirez is a senior vice president and the practice leader for the health, science, and education market sectors at Environmental Systems Design with 28 years of experience in high-tech facilities including R&D, laboratory, manufacturing, and healthcare. 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me