Thorson • Baker and Assocs. Inc.: Flats East Bank Building #4

New construction at an engineered multi-dwelling/retail complex/restaurant and a parking garage/service station.

08/14/2014


Flats East Bank Building #4, under construction. Courtesy: Thorson • Baker & Assocs. Inc.Engineering firm: Thorson • Baker & Assocs. Inc.
2014 MEP Giants rank: 85
Project: Flats East Bank Building #4
Address: Cleveland, Ohio, U.S.
Building type: Engineered multi-dwelling/retail complex/restaurant, Parking garage/service station
Project type: New construction
Engineering services: Automation/controls, electrical/power, fire/life safety, HVAC/mechanical, lighting, energy/sustainability, and plumbing/piping
Project timeline: 12/2013 to 7/2015
MEP/FP budget: $374,000

Flats East Bank Building #4, under construction. Courtesy: Thorson • Baker & Assocs. Inc.Challenges

Thorson • Baker & Associates, Inc. (TBA) is excited to be a part of completing the goals and desires of The Wolstein Group, and Fairmount Properties. This eight-story, 510,449-sq-ft mixed-use apartment building consists of commercial tenants (mostly restaurants) on the first floor, 243 apartments on floors three through eight, and two floors of indoor parking. The new construction includes 59,100 sq ft of retail tenant space, 101,500 sq ft of parking spaces/service area, and 321,249 sq ft for apartments. The most complex challenge of this project was to design a space that maximizes the building’s floor space. Due to the restaurants on the first floor, it was a challenge to get the kitchen exhaust to the roof.

Solutions

Flats East Bank Building #4, under construction. Courtesy: Thorson • Baker & Assocs. Inc.Instead of having 14 to 28 different exhaust shafts to the roof, the firm designed a six-stack system to accommodate the restaurant’s requirement of providing exhaust for possibly 14 restaurants. The building was designed using a water source heat pump system using condensing boilers and cooling tower to limit the size of penetrations through the floor. This project is seeking Enterprise Green Communities certification with the City of Cleveland.

 

 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me