The challenges of maintenance planning

7 tips to get the most out of your process and people

01/26/2012


Excerpted from SMGlobal’s Maintenance Software Blog

Planning maintenance work can be a challenge because it normally consists of two different types of maintenance:

  • Unplanned or emergency maintenance to fix equipment breakdowns or other urgent work as it comes up
  • Planned or preventative maintenance to keep systems/equipment running in peak condition

How does one consolidate and manage these two types of jobs? How can one allocate maintenance technicians and work hours in the daily calendar to get both types of work accomplished? Many maintenance programs have grown organically over the years and end up mainly doing breakdown/ unplanned maintenance. Technicians work in fire fighting mode and preventative planned maintenance typically takes a hit. Not doing preventative maintenance on time (or not at all!) results in further unexpected equipment breakdowns and further emergency maintenance work.

Maintenance Planning Tips

  1. Since unplanned/ breakdown maintenance by its very nature is unpredictable, try to build in buffer time to handle such work. Break each day or week into periods for planned maintenance based on category A (must be done), B (should be done sometime soon) and C (nice to do). Unplanned maintenance can be scheduled as needed around time for category C or even category B maintenance. This can help prevent cascading maintenance issues and associated continuous firefighting.
  2. Make sure to allot enough time and resources for regular preventative maintenance in the maintenance plan
  3. The operating principle when handling any large multi-day, multi-team maintenance job should be “divide and conquer”. Break the whole job down into separate tasks that can be done by different teams or personnel. Here a good CMMS program can help you split the job into separate tasks and “chain” them together so that each sub-task is completed when the prior one is done
  4. Get a good maintenance management software product (CMMS software) that will help you manage both unplanned as well as planned maintenance in a single interface.
  5. Remember that estimates should be based on the person who will be doing the job not on the experience of someone who may be an expert at this job. Inexperienced personnel will take more time to complete many jobs. Having unrealistic estimates will cause backlog and can completely ruin an otherwise well thought out maintenance plan.
  6. When making maintenance plans build in time for recording, updating & reviewing information. Otherwise these elements will be the first to be skipped.
  7. Put together a maintenance calendar of work to be done in the next month, quarter or year by equipment/ and location. This can be useful to show & discuss with production/ operations managers. Items may need to be rescheduled or grouped together to reduce the time equipment is unavailable due to maintenance work or identify conflicts due to production/ operations deadlines. This is another area where a good CMMS/ maintenance software can help since it makes it easier to reschedule and move around jobs.

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me