Texas State University

Energy audits; Texas State University; EEA Consulting Engineers

08/15/2013


This image shows the entry sign to Texas State University. Courtesy: EEA Consulting Engineers

Engineering firm: EEA Consulting Engineers
2013 MEP Giants rank: 88
Project: Texas State University
Address: San Marcos, Texas, United States
Building type: School (college, university)
Project type: Energy audits
Engineering services: Cx/Retro-Cx, HVAC, Lighting
Project timeline: June 2012 to December 2012
Engineering services budget: $175,500
MEP budget: $175,500

Challenges

EEA conducted an energy audit of campus buildings such as Emmett and Miriam McCoy Hall. Courtesy: EEA Consulting EngineersThe timeline was a challenging aspect of this project. EEA's intent was to get the energy audit to the owner as quickly as possible so that implementation could begin and savings could be realized. The notice to proceed for the audit was given on May 16, 2012. By July 30, 2012, 3 million sq ft of space in 40 buildings had been surveyed and analyzed, and the first draft of the report had been delivered to the owner.

Solutions

To meet the compacted schedule, EEA gathered all available personnel resources to complete site work, process field data, identify energy conservation measures (ECMs), and compile the final report featuring ECM descriptions and associated paybacks.

Watch a video from EEA Consulting Engineers on this project.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me