Test leads change tip length with one twist, earning CAT II-IV safety ratings

Fluke Corporation’s TL175 test leads feature adjustable tips, rugged design and visual wear indicators offer higher safety, increased versatility and improved on-the-job reliability.

05/03/2011


Fluke Corporation’s TL175 TwistGuard test leads feature a manually adjustable test tip guard for use in different measurement environments. By simply twisting the test lead, the user can change the exposed probe tip length from 4/25 in to ¾ in. When the tip guard is fully extended, the TL175 test leads are safety rated for CAT III 1000 V and CAT IV 600 V use. When the tip guard is retracted, the test leads are safety rated for CAT II 1000 V use.

The TL175 test leads are also Fluke’s first leads with WearGuard insulation. Each test lead is covered by two layers of silicone insulation: red or black on the outside, and white on the inside. If the TL175 test leads become nicked or scuffed and white insulation is visible, the user has a visual warning that the test leads should be replaced.

While the WearGuard indicator shows excessive wear, the TL175 test leads with a long life in mind. The dual-layer silicone insulation resists melting if it comes in contact with hot surfaces and remains flexible in cold situations. The extra-heavy duty strain relief, built into both the probe-end and the plug-end, has been tested beyond 30,000 bends without failure. The universal input plugs work with all popular brands of digital multimeters with 4 mm input jacks.

The TL175 test leads also offer screw threads at the base of the probe. This allows the user to add screw-on clips, probes and specialty tips. The threads improve measurement reliability, while the wide range of probe tips enhances measurement productivity.

Fluke’s TL175 TwistGuard test leads are available at electronic and electrical distributors worldwide.

www.fluke.com

Fluke Corporation

- Edited by Gust Gianos, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me