Ten Tips for Quality Compressed Air

These suggestions are some of the most effective actions that a design professional can take to design a quality pneumatic-air system-and to ensure that it is maintained correctly: Maintain a low dew point, but not lower than what is needed. Filter the air of harmful particulates. Avoid bypasses to filters and dryers. Get as much of the oil out as possible.

03/01/2001


These suggestions are some of the most effective actions that a design professional can take to design a quality pneumatic-air system-and to ensure that it is maintained correctly:

  • Maintain a low dew point, but not lower than what is needed.

 

  • Filter the air of harmful particulates.

 

  • Avoid bypasses to filters and dryers.

 

  • Get as much of the oil out as possible.

 

  • Consider going to an oil-free system.

 

  • Convert to heat-of-compression dryers.

 

  • Consider a desiccant dryer for only part of the system, if only a small part is exposed to the outdoors.

 

  • Avoid installing a refrigerated dryer upstream of a heatless desiccant dryer.

 

  • Find and fix leaks.

 

  • Consider variable-speed-drive (VSD) compressors.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me