Technologies used in the Ulmer Automation application

Festo PositioningDrives engineering software helps with appropriate component selection and sizing to optimize mechanical drive and transmission components and motors and to prevent duplication of safety factors, reducing energy costs by as much as 70%.

05/03/2012


High rigidity and low moving mass: The pyramid-shaped, enclosed design makes the robot highly dynamic. At the same time, the handling unit is more accessible and allows faster production. Courtesy: FestoPositioningDrives engineering software from Festo helps with appropriate component selection and sizing to optimize mechanical drive and transmission components and motors and to prevent duplication of safety factors, reducing energy costs by as much as 70%. Supplied ready-to-install and fully pretested, lightweight handling systems such as the high-speed handling Tripod EXPT from Festo are delivered directly to users’ applications. The low weight of the Tripod, with its rod kinematics made up of standard electromechanical components and ultralight carbon fiber rods, ensures the efficient use of drive technology. In the case of the H-gantry, which offers the most dynamic motion of any gantry design, stationary motors for the X- and Y-axes ensure lower moving masses. In control technology systems, for example, the double motor controller CMMD-AS with its coupled intermediate circuits exploits braking energy for recovery purposes.

One million relays a year are produced reliably in different shifts using the Delta robot. Courtesy: Festo“The Festo Tripod robot design needs less space and design time than a handling gantry and is also faster than a SCARA” (selective compliant articulated robot arm), according to Gerd Ulmer, general manager of G. Ulmer Automation GmbH, discussing advantages of the new handling system. He has installed two Tripod handling units on an assembly machine for the automotive components supplier.

“It is also thanks to the Tripod that we have been able to produce around one million relays a year in three variants, working in shifts,” reports the system builder. One of the benefits of the handling system is its flexibility; the system is easy to program using the Festo Configuration Tool (FCT) in combination with the programming language Festo Teach Language (FTL).

Precise control: The robotic controller CMXR positions tools and grippers in three dimensions and forms the basis for the ready-to-install handling system Tripod. Courtesy: FestoFesto’s experts make use of the company’s entire range of more than 30,000 products to select the best drive solution—servopneumatic, electric, or pneumatic—on a technology-neutral basis, working on the principle of “Energy efficiency times mechatronics equals success."

The Tripod is actuated by the robotic controller CMXR, which is able to position tools and grippers in three dimensions. The controller can be used, for example, to link in vision systems such as the intelligent vision system SBO..-Q and thus also handle moving objects.

Also read: Efficiency needs a system approach, depends on individual applications

http://www.controleng.com/single-article/efficiency-needs-a-system-approach-depends-on-individual-applications/02a63574b1.html

- Christopher Haug is with Festo. Edited by Mark T. Hoske, CFE Media, Control Engineering.

www.festo.com 

www.ulmergmbh.de 

http://controleng.com/machinecontrol



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me