In high-technology facilities, building-systems integration is a mixed bag, say engineers, in part because-as always-it depends upon the whims of the client. "The degree of integration of multiple building systems often depends on the owner's organization," says Calvin L. Witt, P.E., of Hayes Seay Mattern & Mattern.

01/01/2001


In high-technology facilities, building-systems integration is a mixed bag, say engineers, in part because-as always-it depends upon the whims of the client. "The degree of integration of multiple building systems often depends on the owner's organization," says Calvin L. Witt, P.E., of Hayes Seay Mattern & Mattern. "For instance, most security-conscious clients have little desire to depend on an outside network or equipment to provide this function. Therefore, security normally has little integration with other building systems."

CUH2A's Steven. R. Rafferzeder, P.E., agrees: "In most cases, security-while integrated-is limited to access control. Larger security projects with CCTV and microwave sensors tend to be on a separate system."

Still, if one department of the owner's organization maintains all building systems, it is likely to depend on communication between HVAC controls and other basic building functions, says Kling Lindquist's Charles A Rowland, P.E. "HVAC systems commonly interface with smoke exhaust and sensing systems, coordinate with daylighting systems or occupancy sensors or communicate with other buildings." Additional control tasks may include operation of vertical transportation and emergency generation equipment.

In addition, if the HVAC direct-digital control systems have UL 864/UUKL listings, they can handle many smoke-control functions by means of inexpensive software, rather than by engineering hardwired connections to the systems, adds Witt.

The question of how and whether to integrate with fire-alarm systems is a point of much concern, however. "Fire-alarm systems also need to be highly reliable and supervised," Witt observes, "but the HVAC system needs to react to fire detection either by shutting down or by going to a smoke-control cycle." Also, fire departments generally prefer having intuitive, easy-to-use control panels to aid in fire-fighting and executing smoke-purge functions.

Other external factors affect the decision to integrate, says Carter & Burgess' David Niemann, P.E.: "Building codes and system reliability issues sometimes work against systems integration, although open protocols and the wider use of fiber-optic transmission systems will allow integration to occur more effectively."





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me