Sustainable Water System Design

When undertaking projects, especially in a desert or tropical climates, it is important to consider sustainable technologies for water-system design. And anywhere a project is located, energy efficiency should be a key sustainability concern.Domestic hot-water storage is a large energy consumer.

02/01/2001


When undertaking projects, especially in a desert or tropical climates, it is important to consider sustainable technologies for water-system design. And anywhere a project is located, energy efficiency should be a key sustainability concern.

Domestic hot-water storage is a large energy consumer. The formerly common practice of lowering the storage temperature has proven to cause other problems, so one can be left with the need to store water at 140 degrees.

High-efficiency water heaters with improved insulation systems should be considered. Point-of-use electric heaters can reduce the quantity of stored water, simplify thermostatic mixing-valve piping and lower recirculation losses. Similarly, low-consumption fixtures can reduce the demand for hot water, and self-regulating heat-tracing reduces recirculation losses. While many of these solutions reduce energy at the meter, it is at the cost of using more global energy.

A related system is wastewater-heat recovery . This commercially available system uses a falling-film heat exchanger to extract energy from the waste stream and transfer it to incoming cold water. For buildings with high hot water usage, this can save a lot of energy. Because the drainage piping is arranged to recover the warmest water-which is close to the incoming cold water-this improves performance.

On-site biological waste treatment is also making inroads on highly sustainable projects. Turnkey solutions treat the waste stream in such a way as to have no net increase in required off-site waste treatment.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me