Sustainable strategies for data centers

Andy Baxter, PE, Page principal and director of MEP engineering discussed three trends related to sustainable strategies for the mission critical data center market.

02/23/2017


Andy Baxter, PE, Page principal and director of MEP engineering discussed three trends related to sustainable strategies for the mission critical data center market. Courtesy: PageEngineering clients typically want to investigate and integrate energy-efficient and sustainable solutions based on return on investment (ROI) or total cost of ownership (TCO). Enterprise data center owners and operators tend to be more willing to look at much longer ROI or TCO periods to see benefits. They are also looking at public-perception benefits as well as how this works into their overall business model. Owners and operators of colocation data centers, which provide access to multiple clients, generally focus on their bottom lines, resulting in shorter ROI or TCO periods. Although they do care about public perception and energy efficiency, their primary concern is to attract customers. This does not mean that they aren’t trying to be sustainable or energy-efficient. They just have a different set of business priorities

Clients are concentrating more on reduced power-usage effectiveness (PUE)—the ratio of total facility energy over information technology (IT) equipment energy—and overall operating costs. Page is seeing more evaluations and decisions moving toward efficient and sustainable designs as this field continues to receive public exposure.

Changing attitudes regarding LEED certification

There continues to be a desire to obtain a LEED certification at some level. However, it’s often more of a marketing decision rather than a requirement to be sustainable. Enterprise data center owners are much more likely to make sustainable selections as long as they do not add risk to the facility. On the colocation side, those decisions are almost always about marketing. Looking at the efficiency of the IT equipment itself would have a much bigger impact on the overall sustainability of a facility.

New strategies for making data centers more sustainable

Ideal services would include cooling solutions using direct or indirect economizers, direct evaporative cooling, liquid cooling and heat recovery using data center energy to heat domestic and heating hot-water systems for other parts of a building. In general, it is recommended that evaluating all aspects of energy-efficient design—including cost, sustainability, marketing, risk management and how it will impact a project—before deciding on a particular solution.

Andy Baxter, PE, is principal, mission critical at Page. Page is a CFE Media content partner.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me