Striking a Limit on Lightning Costs

Up to 30% of all power outages are attributable to lightning, at a cost of almost $1 billion annually, say researchers at the Electric Power Research Institute (EPRI). One new product designed to help limit resulting equipment damage combines wireless technology with a battery backup system to take connected PCs and other machines offline when threat arises.

06/01/2003


Up to 30% of all power outages are attributable to lightning, at a cost of almost $1 billion annually, say researchers at the Electric Power Research Institute (EPRI). One new product designed to help limit resulting equipment damage combines wireless technology with a battery backup system to take connected PCs and other machines offline when threat arises. And research now underway is looking at transmission-tower designs that could help dissipate lightning-related surges more effectively.

Storm Shelter Electronics, based in Savannah, Ga., expects to introduce its StrikeUPS this summer. The device incorporates a wireless pager set to receive alerts from the National Lightning Detection Network, a private network of lightning sensors. When the network sends an alert that lightning has been sensed in the area, the device switches connected equipment to a battery backup capable of providing up to 45 minutes of power for as many as three appliances. An audible alarm warns that the switch is about to occur, at which point users can override the operation. An all-clear page transfers equipment back to the connected grid power supply.

The manufacturer claims the device can withstand surges of up to 35,000 volts, significantly more than the standard household surge protector. Units are expected to cost approximately $495. Users also will need to subscribe to the National Lightning Detection Network, at $9.95 per month.

To help keep those surges from ever reaching the outlet, researchers at EPRI now are studying new ways to limit the impact of lightning. Scientists are looking at the dynamic resistance of ground electrodes and concrete tower footings, along with the dielectric properties of underlying soils, in hopes of improving current grounding guidelines.

Investigators know that the resistance properties of the concrete footings vary with the magnitude of any given lightning strike. But algorithms attempting to model that variance have, so far, been based on limited measurements and have not accurately represented real-world lightning storms, according to EPRI.

Recent EPRI studies have focused on the electrical properties of various soil types, including sand, clay, loam and crushed rock, to better understand the interaction of soil and electrodes. In addition, researchers measured resistance of full-scale ground electrodes applying current impulses of much higher magnitude than previously used—up to 40 kiloamps.

EPRI will be publishing the findings in a new guidebook for transmission-line grounding systems, scheduled for release this spring. Results also have been incorporated into a new version of the organization's TFlash software, which helps system designers analyze and mitigate lightning's potential effects.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me