Steam boiler with control system

Fulton’s compact, low-footprint, gas-fired Tribute vertical tubeless steam boiler for commercial and industrial applications can operate at sub-9 ppm NOx and includes an advanced boiler control system

04/11/2012


Tribute vertical tubeless steam boilerFulton’s compact, low-footprint, gas-fired Tribute vertical tubeless steam boiler for commercial and industrial applications can operate at sub-9 ppm NOx and includes an advanced boiler control system. It uses a fiber mesh burner, variable-speed fan, and integrated gas train, providing low emissions combustion with only 4 in. incoming gas pressure. Features include full 4 to 1 modulation and a stainless steel jacket. The Fulton SC-750 touchscreen control system shows current boiler status with high-tech display parameters for burner firing rate, stack temperature, steam pressure, boiler water temperature, and stack emissions levels. The module also displays the status of the boiler feed water pumps, de-aerator water temperature, and boiler water level.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me