Statue of Liberty upgrades to plastic

In May 2008, renovation began on the Statue of Liberty Island to remove all galvanized metal HVAC equipment and other corrosive materials. John Culkin, president of C&S Building Services, Farmingdale, N.Y., led a team of five HVAC technicians to install two plastic cooling towers in place of the steel-clad towers, which had begun to rust and rot.

12/01/2008


View the full story, including all images and figures, in our monthly digital edition

In May 2008, renovation began on the Statue of Liberty Island to remove all galvanized metal HVAC equipment and other corrosive materials. John Culkin, president of C&S Building Services, Farmingdale, N.Y., led a team of five HVAC technicians to install two plastic cooling towers in place of the steel-clad towers, which had begun to rust and rot. The Statue of Liberty rests on a granite pedestal inside the courtyard of the star-shaped walls of Fort Wood, built on Liberty Island for the War of 1812. The wet, salty environment of Liberty Island, which is roughly

“We needed a corrosion-proof cooling tower. Even the stainless steel towers they had out there couldn't survive the elements. All the fittings and nuts and bolts had rotted out. We wanted a maintenance-free solution for a wet, salty environment,” said Culkin.

Initially, the project ran into several challenges, such as how to ferry the heavy equipment from the mainland to Liberty Island. If the replacement towers were too heavy, the rigging fees would dramatically increase because a larger, more powerful crane would be necessary. Culkin and the rest of the C&S team managed to avoid the major costs of rigging heavy equipment and provide a corrosion-proof solution to Lady Liberty's problem by contacting Delta Cooling Towers Inc. Delta manufacturers assembled non-corrosive, high-density polyethylene cooling equipment that is easily maintained and impervious to harsh chemicals, bitter environments, and pH deviations.

Over the span of six weeks, Culkin and the five-member C&S team installed a 250-ton Premier tower to cool the museum at Liberty Island, while a smaller 70-ton Paragon tower was installed to cool the interior space of the Statue of Liberty. HVAC-service technicians performed a controls upgrade to the HVAC system including replacing pumps, disconnect switches, and all steel piping on the outside of the statue.

The installation of the plastic towers allows for fewer support materials because the plastic towers are built directly into the steel frame. Along with a reduced number of support materials, the plastic cooling towers' direct-drive Premium Efficiency fans and a 15-year casing warranty provide several design advantages over conventional models. The seamless, one-piece shell eliminates panels, rivets, or hundreds of fasteners that can weaken and deteriorate the internal structure of the tower. In particular, in such a harsh, damp environment, the seamless plastic towers keep water and moisture away from the vital parts of the tower.

In a high-profile location like Liberty Island, accessibility and minimized downtime were mitigating factors in the decision to choose plastic over steel. The plastic towers reduce downtime because any required maintenance can be performed quickly, unlike a stainless steel tower where a whole side could be lost due to rotting. The only emergency outage would be a fan or fan motor, and the units are easily replaced by removing four bolts and replacing the motor.

Information provided by Delta Cooling Towers Inc ., Rockaway, N.J.



AT A GLANCE

Due to its salty, corrosive environment of the Statue of Liberty Island, all of the galvanized metal HVAC equipment had to be removed. C&S Building Services and its five-member team of HVAC technicians contacted Delta Cooling Towers Inc. to install non-corrosive, high-density polyethylene cooling equipment in its place.

The Statue of Liberty received a 250-ton Premier tower to cool the museum and a 70-ton Paragon tower to cool the statue's interior space. HVAC service technicians performed a controls upgrade to the HVAC system including replacing pumps, disconnect switches, and all steel piping on the outside of the statue.

The new cooling towers' direct-drive Premium Efficiency fans and the15-year casing warranty allow for fewer support materials. The seamless, one-piece shell eliminates panels, rivets, or hundreds of fasteners that can weaken and deteriorate the internal structure of the tower. In a harsh, damp environment like Liberty Island, the seamless plastic towers keep water and moisture away from the vital parts of the tower.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me