Stating Sprinkler Facts

In "Just Passing Through," (June 2000), it is indicated that large-drop sprinklers can be used to protect storage with the top of storage height at 35 to 40 feet. Please be advised that these storage heights exceed those allowed for large drop sprinklers by the National Fire Protection Association's (NFPA) code 13 - 1999, Installation of Sprinkler Systems.

11/01/2000


In "Just Passing Through," (June 2000), it is indicated that large-drop sprinklers can be used to protect storage with the top of storage height at 35 to 40 feet. Please be advised that these storage heights exceed those allowed for large drop sprinklers by the National Fire Protection Association's (NFPA) code 13 - 1999, Installation of Sprinkler Systems. Storage to the heights stated can be protected with ESFR sprinklers.

The last paragraph of that section comments on the fact that the development of large-drop and early-suppression fast-response (ESFR) sprinklers has eliminated the need for in-rack automatic sprinkler protection. This is true but limited to certain maximum storage heights. Someone might get the idea that 90- to 100-foot-high automated storage and retrieval systems could be properly protected with ceiling-only large-drop or ESFR sprinkler protection, and that is not the case. Storage to those heights would require ceiling sprinklers plus multiple levels of face and flue in-rack sprinklers.

TODD SCHUMANN

Research Consultant

Industrial Risk Insurers

We want your feedback! Send letters to the editor to Chris Sullivan in care of this magazine or to csullivan@cahners.com.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me