Starter reduces mounting space

Duo Series combination starter from Fuji Electric Corp. of America consists of two components: BM3 series manual motor starters and SC-E series magnetic contactors. Compact, high-performance motor control system conforms to IEC and UL standards and carries the CE mark. System is designed to cut required mounting space in half and reduce the number of wiring steps by 90%, according to Fuji Elect...

12/01/2006


Motors, drives, motion control

Duo Series combination starter from Fuji Electric Corp. of America consists of two components: BM3 series manual motor starters and SC-E series magnetic contactors. Compact, high-performance motor control system conforms to IEC and UL standards and carries the CE mark. System is designed to cut required mounting space in half and reduce the number of wiring steps by 90%, according to Fuji Electric estimates.

BM3 series manual motor starter integrates the functions of a molded-case circuit breaker and thermal overload relay into a compact unit. Two frame sizes are offered: 32 A and 63 A. BM3 series can be adjusted to match the rated current of the motor and the variety of safety features includes large breaking capacity, trip indicator, and terminals with finger protection. Available accessories include snap-on auxiliary and alarm contact blocks.

SC-E series small to medium magnetic contactors offer finger protection as standard equipment. Compact (55-mm) contactor width is equal to the BM3 series motor series to provide a slim appearance when configured together. Other offerings in the series include 45-mm type with BM3R starters and SC-E series contactors to handle motor circuits to 10 hp at 240 V ac and 20 hp at 480 V ac; and 55-mm type with BM3V starters and SC-E series contactors to handle motor circuits to 20 hp at 240 V ac or 40 hp at 480 V ac.

Duo Series makes available a variety of connection accessories, power supply units, and bus bar covers. Modular wiring system is said to feature a reduction in equipment, efficient wiring, protection against exposure to charged parts, and space-saving design. www.fujielectric.com

Fuji Electric Corp. of America





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me