SR motor anatomy: See inside switched reluctance motors

Simple electromechanical structure of switched reluctance (SR) motors offers benefits of robustness and reliability by eliminating permanent magnets, rotor bars, and more - tutorial.

03/09/2010


Control Engineering feature article: Resurgence for SR Motors, Drives? Advances in controls and simulation software help switched reluctance (SR) motors--one of the oldest electric motor types--remain competitive.

 
Simplest possible 1-phase SR motor (a) illustrates the switched reluctance principle. In the more practical 3-phase motor (b), energizing stator phase pair B (for position shown) produces clockwise torque; energizing phase pair C produces conter-clockwise torque. Design variations include more motor phase, stator poles, and rotor poles.
Simplest possible 1-phase SR motor (a) illustrates the switched reluctance principle. In the more practical 3-phase motor (b), energizing stator phase pair B (for position shown) produces clockwise torque; energizing phase pair C produces conter-clockwise torque. Design variations include more motor phase, stator poles, and rotor poles.

 

Simple electromechanical structure of switched reluctance (SR) motors offers benefits of robustness and reliability by eliminating permanent magnets, rotor bars, and more.

Origins of switched reluctance (SR) motors can be traced back to the reluctance machine design of the mid-19th century, making them one of the oldest electric motor types around. The term SR has been in use for about 40 years, where "switched" indicates sequential switching of current among stator phase windings of the motor--necessary to develop a rotating magnetic field (see main article)--and "reluctance" refers to the resistive property of the magnetic circuit.

Simple rotor, stator construction

Rotor structure of an SR motor is very simple, comprising a stack of electrical steel laminations mounted on the motor shaft. The rotor has no windings or rotor bars, no permanent magnets, and no electrical contacts.

Absence of rotor conductors eliminates a heat source, increasing bearing and lubricant life. Lower power losses improve energy efficiency. The low SR rotor losses are especially relevant during starting, when they are actually less than at normal full-load running condition, according to Emerson Motor Co. This permits prolonged operation in the stalled condition, and repeated starting under full load; starting current never exceeds full-load operating current. "Such performance is often not possible with conventional drives because of large rotor electrical losses, and subsequent rotor heating under such conditions," says Rob Boteler, director of marketing at Emerson Motor.

The "salient" pole construction-with gaps between poles rather than a solid circular cross-section-creates a relatively low-inertia rotor which allows for rapid dynamic response and minimizes risk of mechanical damage from shock loads in high-ratio, gear-driven applications, Boteler explains. "Because of its uniquely simple construction, the SR rotor is well suited to operation at high speeds. It can tolerate high levels of vibration and thermal cycling." Absence of permanent magnets brings significant benefits in terms of environmental compatibility, and permits repair of SR motors in the field or in a conventional repair shop.

An SR motor's stator is likewise a simple, robust structure. It consists of singly pitched coils placed over the salient stator poles (see diagram in main article); the coils are easily pre-wound on a bobbin. "Overall [heating] losses in an SR motor are concentrated within the stator and are relatively easily dissipated--in case of a standard totally enclosed machine by conduction to the relatively cool exterior of the motor frame," states Boteler.

Moreover, stator windings--unlike those of an induction motor--are not distributed over many slots, and the phases do not cross each other in the slot or in the end-connections. This reduces insulation stresses and largely eliminates risk of phase-to-phase insulation failure. Simplicity of the coils allows the end windings to be much shorter than those typically found in ac motors. "As a result, energy losses associated with end windings are reduced. This further improves efficiency and permits the design of different SR motor configurations--for example, flat-shaped ("pancake") motors," Boteler adds. www.emerson.com

[Note, this section of the article is adopted from a paper, "Switched Reluctance Compressor Drive," presented by Emerson Motor Co. at EEMODS 2009 (Efficient Electric Motor Drive Systems), Nantes, France, Sept. 2009.]

Fault tolerance

An additional feature unique to SR motors is the ability to continue to operate (and also likely to start) under a phase loss condition. However, the motor would run less smooth and with less torque output. In theory, only one pole pair is required for operation. "This contrasts with ac induction machines, which will fail to operate when you lose a phase," says George Holling, technical director at Rocky Mountain Technologies.

This feature is of particular advantage in applications such as defense, aerospace, and medical, where ability to complete a mission and/or return safely overrides reduced torque output and noise generation. Holling mentions that a 4-phase SR motor can typically maintain 80% of normal starting torque with one phase inoperative. www.rockymountaintechnologies.com

One recent paper that addresses the issue of fault tolerance in SR systems should be of interest to automation professionals. It can be found at
www.scribd.com/doc/24541914/3rd-International-Symposium-on-Electrical-Engineering-and-Energy-Converters

Also, SPEED software, a motor design tool (developed at Univ. of Glasgow, U.K., as a valuable design tool for building SR motors) is available in the U.S. (and the Americas) through the distributor Magsoft Corp. (SPEED stands for Scottish Power Electronics and Electric Drives; it's a consortium.) www.magsoft-flux.com

Also read, from Control Engineering :

- Springtime for Switched Reluctance Motors? (Feb. 2003) ;

- 'Forward to the Past' with SR Technology (Nov. 1999) ; and

- Motors & Drives channel .

- Frank J. Bartos, P.E, Control Engineering Consulting Editor, braunbart@sbcglobal.net. www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me