Spark-ignited engines

The Generac 9.0 L engine for 80kW and 100kW generators and the Generac 12.9 L engine for 150-300 kW generators.

11/19/2012


The Generac 9.0 L engine for 80kW and 100kW generators and the Generac 12.9 L engine for 150-300 kW generators. Courtesy: GeneracGenerac Power Systems has designed and manufactured two new gaseous-fueled engines specifically for use in several Generac Industrial Power systems: The Generac 9.0 L engine for 80 kW and 100 generators, and the Generac 12.9 L engine for 150 to 300 kW generators. In manufacturing its new engines, Generac used stainless steel for the intake and exhaust valves to ensure durability and long life. Stellite, a cobalt-based alloy, makes the valve seats especially resistant to corrosion and wear. Valve angles were reduced to minimize the friction that can result from using dry fuel. Hypereutectic cast aluminum pistons were chosen to resist thermal expansion for tighter clearances that result in quieter operation and longer piston ring life. Manufacturing its own engines also helps Generac ensure that it can deliver products to customers as quickly as possible. Each of the generators using one of the new Generac engines will retain all of its current features and configurable options. Both new engines will also meet all regulatory requirements. 

Generac Power Systems

www.generac.com



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me