Solution for Gas Detection and Environmental Monitoring

VESDA Systems expanded to provide protection against other airborne threats.

09/29/2010


XtralisVESDA ECO by Xtralis uses new or existing VESDA pipe networks to reliably detect smoke in addition to hazardous/combustible gases to ensure air quality. It also integrates with other building management systems for real-time situational awareness and intelligent emergency response, including the activation of demand-controlled ventilation to control costs and save energy.

Invisible hazards can originate from the release of toxic gases, oxygen deficiency, or the presence of combustible gases/vapors. With an ECO detector installed on a VESDA pipe network, air can be conditioned or filtered to remove moisture, dirt and other particulates that can cause traditional gas-detection systems to false alarm or become contaminated. As with fire detection, early warnings of gas leaks or build-up enables countermeasures to be taken to protect personnel, property and business operations.

Each VESDA ECO detector can house up to two gas sensors, and additional detectors can be added easily to the pipe network to monitor more gases if required. In its initial release, the solution can be configured to detect ammonia, carbon monoxide, hydrogen, hydrogen sulfide, methane, nitrogen dioxide, oxygen, propane and sulfur dioxide.

VESDA ECO provides point, zone, or total-area coverage to suit different applications in a wide array of environments, including  battery-charging rooms, underground utility tunnels, boiler rooms, manufacturing facilities, parking garages and transportation centers. The systems easily integrate with fire alarm control panels (FACP), programmable logic controllers (PLC), HVAC systems, and building management systems (BMS) to provide real-time situational awareness for intelligent emergency response. No construction or electrical conduit is required.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me