Solar Fuses

The first Class RK5 fuse listed to the new UL photovoltaic (PV) fuse standard.

09/21/2010


Cooper BussmannThe new Cooper Bussmann PVS-R solar fuse provides high amp ratings with the required fast-acting response to low photovoltaic DC faults. The PVS-R fuse is the first fuse of its kind to achieve a UL 2579 Listing for low-voltage fuses – fuses for photovoltaic systems. With a dual 600Vac/dc rating, the PVS-R fuse is designed to meet the higher amperage levels of today’s larger solar power systems, while withstanding extreme high and low ambient temperatures, routine cycling, and opening under low level fault current conditions. Typical competitive offerings provide only traditional time-delay fuses that are not well suited for solar power system protection.

Unlike AC systems, the available short-circuit current in photovoltaic (PV) systems is limited and requires the overcurrent protective device to operate effectively on low levels of fault current. For this reason Cooper Bussmann has conducted extensive research and development of fuses that are specifically designed and tested to address the unique overcurrent protection needs of PV systems. This includes testing in ovens to simulate actual application ambient temperatures. Cooper Bussmann also provides time-current curves which follow as close as possible to actual field applications.

Available in ratings from 20 to 600 amps, the PVS-R fuse is well suited for use in recombiner boxes and DC safety switches that operate at higher current levels, but experience the same low-level fault current conditions as combiner boxes and PV strings and arrays.

The new PVS-R fuse is available to meet circuit applications up to 600A. Also, as a standard Class RK5 fuse meeting UL 248-12, it is easy to apply and install in traditional fuse blocks and DC safety switches.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
April 2018
VRFs, lighting controls, BIM coordination, and more
March 2018
Sizing water pipes, ASHRAE 90.1, recovering waste heat, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me