Smart seismic expansion loop

The Seismic BreakAway coupling is designed for seismic events when hanger rods are too short to allow the full-rated movement of seismic expansion loops.

02/09/2015


The Seismic BreakAway coupling is designed for seismic events when hanger rods are too short to allow the full-rated movement of seismic expansion loops. Courtesy: MetraflexMetraflex's Seismic BreakAway coupling is designed for seismic events when hanger rods are too short to allow the full-rated movement of seismic expansion loops. The coupling is designed to separate at a preset load greater than the seismic joint's static weight. This allows the loop to move freely, preventing further damage. After activation, the reusable coupling can be reset and used again with the seismic joint. In nested loop installations, multiple BreakAway couplings can be used to support long return bends. The couplings can also be used with saddles to prevent long flexible legs on large seismic loops from sagging.

Metraflex

www.metraflex.com 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me