Smart power management system chip for automotive applications

The austriamicrosystems AS8650 smart power management System Basis Chip, combines a dc-dc converter and a high-speed transceiver on one chip.

12/03/2010


austriamicrosystems, a designer and manufacturer of high-performance analog ICs, announced the AS8650 smart power management System Basis Chip (SBC) which is allegedly the first to combine a dc-dc converter and a high-speed transceiver on one chip. The AS8650 features high efficiency of 85% minimum over all operation use-cases, while high integration reduces cost, space and development time for engine control units (ECU) with a high-speed CAN interface.

austriamicrosystems AS8650 SBC

The AS8650 SBC includes three LDOs (low-drop-out voltage regulators) with programmable outputs from 1.8 V to 3.3 V. Each LDO is powered by the embedded dc-dc converter which can supply up to 500 mA to power the microcontroller, sensors, actuators and other components. Integrating the dc-dc converter dramatically reduces power losses compared with commonly used voltage regulators that convert the automotive battery voltage to 5 volts. In order to enable individual voltage supplies, three programmable LDOs are embedded in the chip. The AS8650 also includes a highly flexible watchdog unit with three monitory timing functions -- startup, window and shutdown -- which allow the timing to be changed, and features to be enabled via either SPI or I²C settings.

The AS8650 System Basis Chip provides a high-speed CAN interface for up to 1 Mbps communications and conforms to ISO 11898. In addition, the IC can enter into operation mode via a remote wake-up sequence on the CAN bus lines or with the local wake-up pin. Other features include brown-out indication, output voltage monitoring, remote and local wake-up, and automatic thermal shutdown protection.

Harald Gall, Automotive Marketing Manager at austriamicrosystems, stated, “With the AS8650, designers have an SBC for automotive control units that offers high integration and high efficiency in one IC. Designed for high-end power management for next-generation automotive applications, the AS8650 is the first smart power management device of a planned family. A pin-compatible IC with a LIN interface will follow in 2011. Alternative solutions require more space and development time or are not able to optimize power losses.”

Specified over an operating temperature range of -40 to +105°C, the AS8650 is offered in a lead-free 36-pin 6 x 6 mm QFN package.

www.austriamicrosystems.com

austriamicrosystems


- Edited by Amanda McLeman, Control Engineering, www.controleng.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me