Small motors: Nidec Copal sub-miniature step motors in 4, 5, 6, 10 mm sizes

Tiny step motors: Nidec Copal developed a new family of sub-miniature step motors; the smallest is a the LPD4 with a 0.157-in. (4 mm) outside diameter by 0.32-in (8.5 mm) axial length, rated at 3 V dc input.

11/06/2009


Enlarged to show detail...

Nidec Copal 4 mm, 5 mm sub-miniature step motors
Nidec Copal 4 mm, 5 mm sub-miniature step motors

Torrance, CA - Nidec Copal has developed a new family of sub-miniature step motors with the LPD4 (4 mm) and LPD5 (5 mm) representing the smaller of the four member step motor family. The Nidec Copal model LPD4 is a 0.157-in. (4 mm) OD by 0.32-in. (8.15 mm) axial length step motor rated at 3 Volts dc input. The 22.5 degree per step motor develops a holding torque of 0.023 ounce-inches. Maximum pull in speed is 1600 pulses-per-second (pps). Maximum pull out speed is 3000 pulses-per-second. The larger LPD5 model is a 0.197-in. (5 mm) OD by 0.165-in. (4.2 mm) axial length furnishing 0.01 ounce-inches of pull in torque over a wide speed range up to 2000 pps. Input voltage is 4.3 vdc and the LPD5 step angle is 18 degrees per step. Typical applications include miniature medical pumps, fiber optic actuators, camera focus drives, etc. For further information about the LPD4, LPD5, and the two larger LPD6 and LPD10 models, please contact Nidec Copal (USA) Corp. www.nidec-copal-usa.com.

Also read from Control Engineering :

- Small motors market surging in Americas ; and

- Rise of the PM (permanent magnet) machines .

- Edited by Mark T. Hoske, editor in chief, Control Engineering , www.controleng.com





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me