Small Grids Could Solve Big Problems

A new way of organizing distributed generated resources could help avoid some disruptions that devices like microturbines and fuel cells can cause to the larger grid. Also, the new strategy could provide extra control and power security for facility owners and managers. A report, released in April by the Consortium for Electric Reliability Technology Solutions (CERTS) describes how connecting t...

06/01/2002


A new way of organizing distributed generated resources could help avoid some disruptions that devices like microturbines and fuel cells can cause to the larger grid. Also, the new strategy could provide extra control and power security for facility owners and managers. A report, released in April by the Consortium for Electric Reliability Technology Solutions (CERTS) describes how connecting these resources through advanced controls technology could allow the larger grid operator to treat this new "microgrid" as an equal partner, and allow the facility to operate independently if the larger grid goes down.

Key to the concept are microsource controllers, advanced power electronics that control the interface between the power-generating appliances and their surrounding alternating-current environment. In this way, the distributed resources can be treated as an integrated entity, rather than as a series of isolated power sources. This approach could make for easy separation and reconnection to the grid in case of supply disturbances.

"Integration of Distributed Energy Resources: The CERTS MicroGrid Concept," can be downloaded at: certs.lbl.gov/pdf/certs_mgrid.pdf

From Pure Power, Summer 2002.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me