Single function temperature calibrators

Temperature and 4 to 20 mA signals from Fluke's 712B RTD and 714B Thermocouple Temperature Calibrators can be measured and viewed simultaneously on large backlit display for easy transmitter calibration.

04/08/2014


Temperature and 4 to 20 mA signals from Fluke's 712B RTD and 714B Thermocouple Temperature Calibrators can be measured and viewed simultaneously on large backlit display for easy transmitter calibration. Courtesy: FlukeFluke's 712B RTD and 714B Thermocouple Temperature Calibrators allow instrument, process, and plant maintenance technicians to quickly and easily test process temperature instrumentation. The Fluke 712B measures and simulates 13 different resistance temperature detectors (RTDs) types and resistance, and the 714B measures and simulates 17 different thermocouple types as well as millivolts, to verify process sensors by direct comparison of measured versus reported temperatures.

The calibrators also measure 4-20 mA signals with 0.001 mA resolution while simultaneously sourcing a temperature signal - with both readings displayed on the large, backlit display for easy transmitter calibration. They can scale the measured mA to the programmed 0 and 100% temperature settings to verify the 0 and 100% values scaled in a temperature transmitter. They also feature linear ramp and 25 percent step auto-ramp based on 0 and 100% settings.

Settings at power down are saved for easy restart of tests when the calibrator is powered back up. Both calibrators have built-in magnetic hanging tools for easy mounting while taking measurements.

Fluke Corp.

www.fluke.com 

- Edited by CFE Media. See more Control Engineering process sensor and actuator products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me