Simple Lighting Upgrades Save Valvoline $1.65 Million

Within the last decade, breakthroughs in lamp and ballast designs have driven significant improvements in lighting quality and efficiency. In addition to energy savings, longer-life light sources and new fixture designs can also reduce lighting system maintenance costs. But nearly 90% of commercial buildings in the United States were constructed before 1985, and consequently, did not incorporat...

02/01/2003


Within the last decade, breakthroughs in lamp and ballast designs have driven significant improvements in lighting quality and efficiency. In addition to energy savings, longer-life light sources and new fixture designs can also reduce lighting system maintenance costs.

But nearly 90% of commercial buildings in the United States were constructed before 1985, and consequently, did not incorporate these technologies. But a growing number of companies are realizing long-term positive cash flow by upgrading to these systems. Compared to other building improvements, a lighting systems upgrade is a low-risk, short-payback investment that can produce up to 30% annual energy savings.

A case in point comes from Eco Engineering, a Louisville, Ky.-based energy services company that undertook the installation of new energy-efficient lighting technology in 344 Valvoline Instant Oil Change stores in 11 states. These projects will save Valvoline—a division of Ashland Oil—an estimated $1.65 million over the next 10 years.

"From a financial perspective, Valvoline will start seeing savings immediately and those savings will be significant—$165,000 annually," says Brian Roth, Eco Engineering product manager.

Burke says Eco's goal was to install energy-efficient lighting that would reduce utility costs by approximately 50% while maintaining or improving existing lighting conditions at each store. Eco's engineers produced a design that called for the installation of customized reflectors. This design allows the facilities to maximize their energy savings while improving lighting in the pit areas, which enhances safety and productivity.

Installation details

In all, 5,200 magnetic ballasts were replaced with electronic ballasts, which are claimed to increase fixture efficiency up to 30% by reducing ballast losses, fixture temperature and system wattage. And because they operate at cooler temperatures, they also last longer than standard magnetic ballasts.

In addition, nearly 10,000 T-12 lamps were replaced with more energy-efficient T-8 lamps. Approximately 2,400 T-8 lamps were installed into new vapor-tight fixtures to improve the lighting in the pit areas and minimize maintenance in such areas prone to high moisture levels. Lamp counts were reduced in both areas as a result of the improved light quantity created from the use of the reflectors.

"It's very rewarding to complete a project of this magnitude. From an installation perspective, we were able to complete the installations without interrupting the day-to-day business activity at the stores. From a customer service perspective, Valvoline facilities are now safer and more productive," says Roth.

Energy savings for the entire project in kilowatt-hours equaled 1.85 million annually. This is the equivalent environmental value of removing 263 cars from U.S. roads annually. The estimated payback for the project is just over four years, with a 20% to 25% return on investment.





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me