Silent Knight points fire protection in right direction at Staybridge Hotel

Staybridge Suites, Cleveland, 123-room franchise hotel’s fire protection system failed to meet the fire protection system standards and the hotel chain utilized the Life Safety Systems, Cleveland, engineering firm Thorson Baker and the Silent Knight system from Honeywell Life Safety group.

09/05/2007


Staybridge Suites, Cleveland, aSafety group.

The Farenhyt IFP-1000 Analog/Addressable Fire Alarm Control Panel (FACP) has 1,000 addressable points and is used in mid-to-large-sized jobs such as schools, universities, hospitals and hotels. The system has one signaling line circuit that supports expansion of as many as seven more signaling line circuits. The FACP also has a built-in, dual-line digital fire communicator and supports remote enunciators, serial/parallel printer interface and system sensor intelligent device protocol or Hockiki devices. The system uses standard wire, which requires no shielded or twisted pairs.


Eight RPS-1000 Intelligent Power Modules power the system and the RPS-1000 adds 5.0 amps of power while supporting its own backup battery and monitoring the AC power. The Flexput circuits are programmable as notification appliance circuits, continuous, resettable or door holder power and conventional initiation circuits for 2 or 4-wire smoke detectors and contact devices. The devices can house signaling line circuit cards, which are determined by their location in the vertical riser structure.


The Staybridge fire safety standard also modified the life safety system by requiring smoke detection methods even in the buildings that possessed a sprinkler system and a beam-style smoke detection system across the lobby area.

For more about systems from Silent Knight, click here .





Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me