Servo drives simplify control, synchronize motion

AKD PDMM and Basic servo drives from Kollmorgen are designed for simple single axis control and up to 128 axes of complex and programmable synchronized motion.

02/06/2013


AKD PDMM and Basic servo drives from Kollmorgen are designed for simple single axis control and up to 128 axes of complex and programmable synchronized motion. Courtesy: KollmorgenAKD PDMM and AKD Basic servo drives from Kollmorgen enable OEMs to simplify the design, reduce the size and improve the performance of virtually any machine.  Scalable solutions enable machine designers to leverage a single drive platform to satisfy unique motion needs – from simple single axis control up to 128 axes of fully programmable and tightly synchronized motion – across machine designs.

AKD Ethernet-based servo drives enable machine builders to standardize on a single drive family with a common Graphical User Interface (GUI) across the power range (up to 24 Arms continuous and 48 Arms peak). This results in optimized machine performance, throughput and accuracy across multiple applications, while minimizing engineering time and costs associated with stocking, understanding and programming multiple types of drives. These drives offer pug-and-play commissioning for instant and seamless access to everything in a machine. AKD servo drives are available in a wide range of connectivity and control options including EtherCAT, EtherNet/IP, CANopen, Profinet as well as Analog, and pulse train command control options.

AKD PDMM combines a high-performance multi-axis motion controller, complete IEC61131-3 soft PLC, EtherCAT master, and AKD servo drive in a single, compact package. This enables OEMs to lower machine costs, reduce panel space by 50 percent or more and simplify wiring and integration, while increasing system flexibility, scalability, and motion performance. AKD PDMM is designed for applications where precise synchronization of multiple axes of motion is vital, and can reduce the time required to commission complex systems from weeks or more to days or even hours. 

AKD Basic incorporates a programmable single-axis motion controller into the existing AKD drive footprint, enabling OEMs to build a more compact and cost-effective machine by eliminating the need for a separate PLC. The registration correction, camming, s-curve and free-form motion profile capabilities delivered by the integrated motion controller, combined with the simplicity of Basic programming language and a built-in Program Editor with debugging tools, enables machine builders to reduce development time by up to 70 percent and to easily execute complex processes, faster than is possible with conventional servo drive-based options.

Kollmorgen

www.kollmorgen.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me