Serving Up a New Look for an Old Dining Hall

Texas A & M University's Sbisa Dining Hall in College Station, Texas, served its first meal in 1913. The 100,000-square-foot building is the oldest dining hall on campus and was the only building large enough to provide a meeting place for the student body.

11/01/2000


Texas A & M University's Sbisa Dining Hall in College Station, Texas, served its first meal in 1913. The 100,000-square-foot building is the oldest dining hall on campus and was the only building large enough to provide a meeting place for the student body.

With its last renovation being in the 1970s, years of multiple use and earlier remodelings had led to deterioration and architectural confusion.

Now, the building is being remodeled both to restore it to a more traditional look and to update the kitchen and cafeteria to a contemporary type of service.

Previously, the kitchen incorporated three large exhaust fans, two of which exhausted four extremely large hoods in the kitchen. The third fan served several smaller hoods located in the serving area.

The new kitchen area plans departmentalize food preparation and cooking stations on the main and basement levels. Fifteen new hoods were installed to handle 56,000 cubic feet per minute of exhaust air.

According to Rick Eicher, lead engineer from Texas-based Day Brown Rice Engineering, Inc., the new design allows users to activate only the hood that is needed. In this way, energy will be conserved. In fact, controls for the hoods will be tied to the building's energy-management system.

One of the most interesting aspects of the renovation is the new ductwork, which has been completely redesigned for the new system and is being installed throughout the building.

Stainless-steel ducts

According to Frankie Jaster, the university's food-services assistant facilities manager, the original duct systems were not user-friendly: "I wanted a round duct; it's quieter and easier to clean. I also wanted stainless steel. Stainless steel is normally used for steam-type ducts, but it cleans better and lasts longer than mild steel, and won't rust."

Project engineers identified additional problems-the wood substructure and a lack of available space. They determined that using a traditional duct-and-chase approach would not be cost effective for such a complex project.

A round, insulated grease duct was specified with integral chase that allows a zero clearance to combustibles and requires no welding. This eliminated the cost of welding and fabricating a chase, and allowed contractors extra room to work duct around tight spaces. Specified duct sizing was up to 26 inches in diameter, and it was installed right up to combustibles with no problem.

For more information on the Series 4 Grease Duct from Metal-Fab, Inc., circle 105 on the Reader Service Card on page 91 of this issue.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me