Sequence of events recorders

CyTime sequence-of-events recorders add time protocol for 1 ms time sync over Ethernet.

10/20/2015


CyTimeTM sequence-of-events recorders add time protocol for 1 ms time sync over Ethernet. Courtesy: Cyber Sciences, Inc.Cyber Sciences Inc. announces the addition of Precision Time Protocol (PTP) to CyTime Sequence of Events Recorders SER-3200 and SER-2408. PTP enables sub-millisecond time synchronization over an Ethernet network. The technology is the "hardware-assisted" time-stamping by the special 1588-compliant Ethernet hardware in the SER devices. SERs record what happened and when, to 1 msec; this data is used for root-cause analysis, warning of slow breakers, or to verify proper operation of automatic controls and time-current coordination. SER devices are components of Electrical Power Monitoring Systems (EPMS), Emergency Power Supply Systems (EPSS), and Supervisory Control and Data Acquisition (SCADA) systems in a variety of commercial/industrial installations.

Cyber Sciences Inc.

www.cyber-sciences.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me