Sensors, controls improve beer: Less oxygen, better beer

Oxygen in beer reduces shelf life and can affect flavor. Advanced optical measurement and sensor diagnostic technologies minimizes oxygen, simply and dependably.

12/12/2011


Oxygen in the brewing process is monitored because of its importance on the quality, taste and shelf life of the beer. After fermentation, beer is close to being oxygen free and maintaining this very low oxygen level is important for quality assurance. Therefore O2 uptake during the following separation, filtration, storage and filling processes has to be minimized. To reduce the risk of contamination, permanent and precise oxygen monitoring is required.

The InPro6970i has reduced signal drift and faster response time compared to amperometric sensors guarantees maximum accuracy of the oxygen measurement and allow for enhanced process control. Courtesy: Mettler ToledoContinuous measuring of oxygen concentration places high demands on an in-line O2 system. Such equipment must be easy to install and operate, require minimal maintenance and, most importantly, always measure accurately.

Intelligent optical sensor

The InPro 6970i from Mettler-Toledo delivers at low oxygen levels down to 2 ppb. Based on fluorescence quenching technology, it combines high measurement performance with Intelligent Sensor Management (ISM) functionality.

Optical oxygen sensors offer many advantages over amperometric sensors; reduced and easier maintenance, and long term stability resulting in reduced cost of ownership being only two of them. The only consumable, the OptoCap, has a significantly longer lifetime then amperometric membrane bodies and can easily be replaced within a few minutes. No polarization or liquid handling is necessary. Once the sensor is calibrated it is ready to use.

ISM technology adds to these advantages by simplifying maintenance planning and documentation of all sensor data. Using advanced diagnostic tools, the quality of the sensing element and all sensor components are permanently monitored. Early signs of sensor aging or failure are immediately displayed to the user.

With Plug and Measure, the sensor can be connected to an M400 transmitter, and all data, including calibration and information about the sensor history, e.g. the stresses that the sensor has been exposed to, the number of CIP cycles and much more, are transferred to the transmitter. The system becomes ready for use within a few seconds and no complicated configuration or failure prone calibration at the point of use is required.

http://www.mt.com/InPro6970i

http://www.mt.com/InPro6970i 

www.mt.com/ISM 

Mettler Toledo

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

For other Control Engineering fermentation articles, see below.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me