Self-contained wireless photoelectric sensor

Banner Engineering SureCross Q45 is the world’s first self-contained, wireless standard photoelectric sensor designed for control and monitoring applications, the company said.

08/28/2012


Banner Engineering SureCross Q45 is the world’s first self-contained, wireless standard photoelectric sensor designed for control and monitoring applications, the company said. Courtesy: Banner EngineeringWireless sensing offers advantages when traditional solutions are significantly more costly due to infrastructure requirements—complexities of cables, conduits and installation—operators can quickly integrate a scalable, wireless sensor network to improve efficiency by monitoring and coordinating multiple machines and processes. It was developed from the ground up for industrial automation, according to Banner Engineering. Proprietary power management delivers extended battery life up to five years on two replaceable AA Lithium batteries, depending on sensor and application. It communicates up to 3,000 ft (1 km) line-of-sight minimum. The IP67/NEMA 6P protection can support up to 47 Q45 sensors per gateway.

“The SureCross Q45 was developed from the ground up, exclusively for the demands of industrial automation,” said Scott Pritchard, director of wireless at Banner Engineering. “The proprietary, self-contained battery, radio and sensor solution, featuring easy deployment and untethered communications, provides the functionality, reliability and determinism required for factory applications,” Pritchard said.

The SureCross Q45 is said to be ideal for many applications, including cable replacement, moving applications, remote applications and productivity solutions. To meet diverse application requirements, models are available in polarized retroreflective, convergent visible, remote device interface and fiber optic.

“The flexibility of the SureCross Q45 sets it apart from anything else our customers have used,” said Bob Gardner, senior product manager at Banner Engineering. 

“With performance capabilities ranging from the detection of objects in simple presence/absence or alignment applications to call-for-parts and error-proofing in productivity solutions, the SureCross Q45 can accurately connect and solve applications that were difficult, costly or nearly impossible with conventional technologies,” Gardner added.

 

www.bannerengineering.com

 

- Edited by Mark T. Hoske, content manager, CFE Media, Control Engineering, and Plant Engineering, mhoske@cfemedia.com.

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me