School HVAC Noise Levels a Case of Internal Affairs?

There are many reasons for poor performance in school, but one that isn't widely recognized is ventilation noise in classrooms. Ricardo Gamboa, manager of engineering and technical services for performance materials for Denver-based Johns Manville believes it's not an issue to be taken lightly. "It is a big problem.

08/01/2004


There are many reasons for poor performance in school, but one that isn't widely recognized is ventilation noise in classrooms. Ricardo Gamboa, manager of engineering and technical services for performance materials for Denver-based Johns Manville believes it's not an issue to be taken lightly.

"It is a big problem. We are adults. If we only hear one or two words, we can make [the rest] up, we can bridge and get a sense of what is being said," he says. "Kids have a very limited vocabulary, and they can't do that, so they lose all sense of what is being said or the actual meaning of the conversation."

Gamboa has high hopes for a standard that addresses this issue. ANSI S12.60, Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools , was recently developed by the Acoustical Society of America. However, it has yet to be adopted into code.

In the meantime, Gamboa and his Johns Manville colleagues push for what they see as an important tactic in controlling acoustics—and temperature—in classrooms: internal duct lining. Eric Schakel, market manager of commercial air-handling products for the company, explains that there was a trend away from installing internal duct insulation in schools over the last 10 to 15 years, due to fears of potentially harmful effects of fiberglass. However, Charles Cotrell, director of technical services for the North American Insulation Manufacturer's Association, notes that in 2002, the International Agency for Research on Cancer concluded that fiberglass is not known to be a carcinogen to humans. As a result, Schakel says, his company has noticed an increase in the use of fiberglass duct lining.

Additionally, Schakel points to ASTM C1071, Standard Specification for Fibrous Glass Duct Lining Insulation . While this standard doesn't directly address classroom acoustics, it does cover "fibrous glass insulation used as a thermal and sound absorbing liner for interior surfaces of ducts." As such, says Schakel, it allows engineers to specify insulation based on noise absorption and thermal capabilities, whereas in the past, engineers often specified various thicknesses and materials without a point of reference as performance.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me