Sampling pump module simplifies gas monitoring in remote areas

New SM100 sampling pump module from General Monitors simplifies gas monitoring for wet wells, aluminum smelting, emissions monitoring of soil samples, landfill gas monitoring, printing press operations, and wastewater treatment.

05/09/2012


The new SM100 Sampling Pump Module from General Monitors draws combustible or toxic gases at 0.05 to 1 LPM from monitored areas to a gas detector, making it easier and cost effective to measure potentially hazardous gases in areas that are too remote, inaccessible, or too cold, hot, or wet for direct sensor monitoring.

SM100 gas sampling system, Courtesy: General MonitorsThe user-friendly SM100 Sampling Pump Module supplies gas for up to three gas detectors, which is useful formonitoring multiple gases in a single line. The SM100 features a low flow indicator, which informs the end user if flow is insufficient for gas detection.  It also includes a trouble relay thatprovides a local signal indication of the low flow condition.

The SM100 Sampling Pump Module reduces plant operating costs by simplifying operation and maintenance. Its rugged design and 316-stainless steel construction make it suitable for gas detection service in a variety of harsh industrial environments. Areas particularly suited for monitoring with the SM100 include ducts carrying combustible or toxic gas, wet wells, sewage dryers, printing drying ovens, and storage tanks.

The SM100 is available in two configurations, an aspirated model that is used with a compressed air source and a DC pump module. The aspirated model is designed for use with instrument grade aspirator air, up to a max aspirator pressure of 30 psig (206 kPa).

The SM100 operates at a wide temperature range of -4 F to +131 F (-20 C to +55 C) and at a humidity range of 15-95% RH, non-condensing. Its enclosure is C-UL-US approved and designed for use in Class I, Div. 1, Groups A, B, C & D.

See other process instrumentation at controleng.com/instrumentation



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me