Safety controller for Profinet networks

The new B&R SafeLogic safety controller allows Smart Safe Reaction technology to be used with Profinet. It's 10 times faster than previous solutions, the company said.

05/10/2012


The new SafeLOGIC model from B&R allows Smart Safe Reaction technology to be used together with Profinet. Courtesy: B&RWith B+R's SafeLogic safety controller is available for Profinet networks, Smart Safe Reaction technology can be quickly and easily integrated into Profinet automation applications. 

Based on openSafety, B+R's Smart Safe Reaction product set is the only integrated safety system that can guarantee response times of 10 ms, which is 10 times faster than previous solutions, the company said. The openSafety real-time safety bus system is not bound to one solution and can be used on all conventional Ethernet-based fieldbus network systems up to SIL 3. 

In industries where Profinet has established itself as the most prevalent fieldbus network, there is considerable interest in open safety technology. With the innovative and high-performance features that Smart Safe Reaction technology can provide in combination with openSafety, user requirements can now also be solved on automated machines and systems that use Profinet. 

Product set for Profinet 

B+R meets this demand with a SafeLogic safety controller model for Profinet. It allows execution of the safety-related application program and also handles monitoring the overall configuration of the application, including its parameters. 

The application on the Profinet master CPU has full access to the signals in the network, regardless of whether standard or safety-related channels are affected. The SafeLogic controller also uses openSafety to monitor the system and shut it down if a safety requirement is not met. A wide range of proven functions from the Smart Safe Reaction portfolio is available for implementation. This includes, for example, PLCopen-compliant and TÜV-certified function blocks, secure digital and analog input signals, safe temperature signal detection, and much more. 

The SafeLogic controller in this network can also handle signals from openSafety components such as light curtains, laser scanners and variable frequency drives from other manufacturers. 

B+R Automation

www.br-automation.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 

controleng.com/networks

controleng.com/safety



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me