RTM Engineering Consultants LLC: Wilton Brands LLC

Electrical, power; fire, life safety; HVAC; mechanical; plumbing, piping; office building; and building retrofit

08/09/2018


Engineering firm: RTM Engineering Consultants LLC

2018 MEP Giants rank: 86

Project: Wilton Brands LLC

Location: Naperville, IL, United States

Building type: Office building

Project type: Existing building retrofit

Engineering services: Electrical, power; fire, life safety; HVAC, mechanical; and plumbing, piping

Project timeline: October 2016 to November 2017

MEP/FP budget: $139,150

 

Challenges

RTM provided engineering and design of the MEP systems for the 86,000-sq-ft tenant build-out for Wilton Brands' corporate headquarters at 535 East Diehl Road in Naperville, Illinois.

The new location features five test kitchens, a food scientist lab, a decorating room, and in-house video and photography studios. Design of the multi-floor, single-phase project included specialty areas where upgraded power, supplemental cooling, and HVAC modifications were required. RTM designed building systems to meet the needs of the leading food-crafting company by planning for natural gas piping to kitchen appliances, commercial kitchen hoods, make-up air, grease trap, and dehumidification system for the cake decorating studio.

Unique to the space, RTM's design included a 775-sq-ft server room with a new 100-kva UPS system and incorporated the use of an existing 125-kw generator to provide emergency power to the room.

Solutions

In addition to the specialty areas, the remodeled space features a blend of private offices, workstations, conference rooms, and a cafe/wellness room. The modern, clean space encourages more team collaboration as Wilton was able to now combine all of their departments under one roof.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me