RGB light analysis sensor

The LEX-1000 color light measurement sensor by EMX analyzes light for RGB values on all visible light sources while providing LCD and LED quality.

03/14/2013


The LEX-1000 color light measurement sensor by EMX analyzes light for RGB values on all visible light sources while providing LCD and LED quality. Courtesy: EMX Industries, Inc.The LEX-1000 Color Light Measurement Sensor measures the relative color characteristics of a wide variety of light sources and illuminated objects. The Color Light Measurement Sensor is designed for evaluation of all visible light sources, while providing comparative light measurement. It provides LCD and LED relative color measurement and display quality.

 

The LEX-1000 Color Light Measurement Sensor analyzes light for its constituent RGB (red, green, blue) values.  If the readings of all of the three colors fall within the pre programmed parameters, the sensor issues a discrete signal that indicates a color match.

Other features of the LEX-1000 include four programmable color recognition channels, RGB analog outputs, serial communications via RS232 or USB, and M30 housing for industrial environments. The LEX-1000 also coms with discrete outputs for factory automation systems and a lock out operator so settings can't be changed.

EMX Industries Inc.

www.emxinc.com 

- Edited by Control Engineering. See other sensor product introductions edited by Control Engineering.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Exploring fire pumps and systems; Lighting energy codes; Salary survey; Changes to NFPA 20
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me