Retrofitting HVAC systems in existing buildings

While the mechanical engineering team has much more control over how HVAC systems are designed and how they fit into the facility for new construction, retrofitting HVAC systems to accommodate existing buildings is considerably more challenging.

05/24/2016


While the mechanical engineering team has much more control over how HVAC systems are designed and how they fit into the facility for new construction, retrofitting HVAC systems to accommodate existing buildings is considerably more challenging. Existing buildings were built to meet older codes and design requirements, which makes it difficult to meet current codes and standards that affect energy efficiency, indoor air quality, indoor environmental quality, and other factors. However, there is a huge opportunity to increase energy efficiency in older facilities.

Engineers must determine which HVAC system components should be included in a retrofit, how new equipment and supporting infrastructure will fit existing spaces, and how to bring systems in existing buildings up to local code. Designers also must tackle performance issues such as air balancing, upgrading HVAC controls and building automation, indoor air quality, and aligning lifecycle cost analysis (LCCA) with owner/client expectations. With regard to building envelope, resolving sources of leakage and indoor contamination in the envelope is considerably more challenging and expensive. Retrofit of existing buildings is challenged both by identifying envelope issues and developing creative solutions to resolving those issues cost effectively.

Learning objectives:

  • The audience will understand the applicable codes and standards: ASHRAE 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings; ASHRAE 62.1: Ventilation for Acceptable Indoor Air Quality; Standard 189.1: Standard for the Design of High-Performance Green Buildings, and International Energy Conservation Code (IECC).
  • Attendees will learn how to identify opportunities to increase energy efficiency through upgraded HVAC systems, building envelope, insulation, etc.
  • Viewers will gain insights on how to calculate the owner's return on investment (ROI) and complete a lifecycle cost analysis (LCCA) when retrofitting specific building types, such as office buildings, hospitals, schools, or mixed-use buildings.
  • Viewers will develop a basic understanding of HVAC retrofit performance delivery issues, such as commissioning, building envelope testing, test-and-balance, and air balancing, and ensuring the new system works in the existing building space.
  • Attendees will learn how to use effective building testing to establish the condition of existing building air and water distribution systems, existing building loads and specific building envelope opportunities.

Presenters:

Jerry Bauers, PE, National Program Executive, Outcome Construction Services LLC, Kansas City, Mo.

Ryan T. Evans, PE, LEED AP, Director of Sustainability, Strategic Partnerships, Henderson Engineers Inc., Lenexa, Kansas

Moderator: Jack Smith, Consulting-Specifying Engineer and CFE Media, LLC



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
August 2018
MEP Giants, lighting designs, circuit protection, ventilation systems, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me