RDK Engineers: Brown Brothers Harriman and Co.

Existing building retrofit at an office building.

08/14/2014


Engineering firm: RDK Engineers
2014 MEP Giants rank: 27
Project: Brown Brothers Harriman & Co.
Address: Boston, Mass., U.S.
Building type: Office building
Project type: Existing building retrofit
Engineering services: Automation/controls, electrical/power, fire/life safety, HVAC/mechanical, energy/sustainability, plumbing/piping, and other
Project timeline: 6/19/2012 to 10/1/2013

Challenges

The entire space was considered a mission critical facility that required design of infrastructure so the entire office could be on a backup generator. The space also required design of a full-service cooking kitchen in a high-rise building to accommodate 900 employees. In addition, all MEP systems, controls, and ductwork had to be designed new from scratch on all floors. Finally, the project had to be completed in a tight time frame, an 8-month construction period.

Solutions

There was not enough space in the building to add an additional generator to back up all the systems in the new space, so an intricate electrical infrastructure was designed where power is diverted by priority to equipment in the event of an outage. To give the client its full-service cooking kitchen, RDK designed an HVAC system to bring make-up air and exhaust up through the building by using an abandoned elevator shaft. Last, the client wanted a floating ceiling. Ductwork and piping was kept as hidden as possible and various fan power boxes were bench tested to find the quietest equipment to ease acoustical concerns.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me