ProSense motor monitoring relays: AutomationDirect

AutomationDirect's expanded proSense line includes phase monitoring, alternating and pump seal failure relays.

03/24/2010


 

The expanded AutomationDirect proSense line includes relays for phase monitoring, alternating and pump seal failure.

 

AutomationDirect proSense line includes phase monitoring,  alternating, and pump seal failure relays.

AutomationDirect proSense line includes phase monitoring, alternating, and pump seal failure relays.

 

AutomationDirect proSense PMRU phase monitoring relays have microprocessor-based design to protect against phase loss, reversal, unbalance, undervoltage and overvoltage conditions. With a variety of user-adjustable settings, PMRU relays also feature a multi-color LED to indicate normal and fault conditions.

The PMRR series provides protection against phase reversal, while the PMRRL series, with an adjustable undervoltage setting knob, protects against phase loss, reversal and undervoltage.
AR series alternating relays feature a three-position selector switch to alternate two loads as normal, or lock the relay to one load or the other. The ARX model is a DPDT cross-wired unit that alternates two loads as normal, or locks the relay to always operate the same load first each time.
Also available are PSFR series pump seal failure relays, which monitor the shaft seals of submersible pumps. Featuring a user-adjustable sensitivity knob, the relays are available in two 8-pin models - SPDT single channel or dual channel relay with two SPNO contacts. Accompanying 8-pin 10 A, 600 V octal sockets are available.
To see the complete proSense motor monitoring relay line, visit www.automationdirect.com.
Also read from Control Engineering :

- Power Protection Devices ;
- ProSense pressure sensor family expands operating range ;
- I/O modules: Find the right mix, says AutomationDirect ; and
- Universal signal conditioners from AutomationDirect .
- Edited by Mark T. Hoske, editor in chief, Control Engineering , www.controleng.com

 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
How to use IPD; 2017 Commissioning Giants; CFDs and harmonic mitigation; Eight steps to determine plumbing system requirements
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me