Project Showcase: University of Chicago Ophthalmology Clinic

The University of Chicago Ophthalmology Clinic is being expanded while remaining operational. The current mechanical, electrical, and fan systems are all being upgraded during the project.

04/19/2018


Ophthalmology Clinic, University of Chicago. Image courtesy: RTM Engineering Consultants.RTM is providing MEP/FP engineering design services for the multi-phase expansion and renovation of the Ophthalmology Clinic within the Duchossois Center for Advanced Medicine (DCAM) at The University of Chicago. The existing 12,000-square-foot space, located on the first floor, is comprised of about half clinic space and half administrative support spaces. In order for the Ophthalmology and Visual Sciences Department to accommodate for future growth as well as specialty testing services, the scope of this project includes expanding the full space for clinical use. The existing clinic needs to stay operational throughout the duration of the project, so RTM is working closely with the architect as well as clinic staff throughout all phases to make sure there are no disruptions to daily operations.

RTM is upgrading the current mechanical system from pneumatic controls into Direct Digital Controls (DDC), which provides a more optimized approach to the space’s mechanical energy usage. RTM is also working directly with the University of Chicago to provide upgrades to the base building systems to replace the exhaust fans with Variable Frequent Drives (VFD), an energy-saving mechanism that allows the building’s system to run at variable speeds.

On the electrical side, RTM is implementing normal, critical and life-safety power to the newly expanded space, and replacing the existing nurse call system throughout. A new wireless Lutron lighting controls system was designed which will provide the facility with more flexibility in controlling lighting from room to room. Additionally, RTM is designing a new layout for overhead paging system, updating the card access security system, and placing cameras for proper coverage for the newly designed video surveillance system.

A particularly challenging aspect of this project concerns the plumbing design for many of the new spaces. The floor cannot be penetrated due to a ComEd vault directly beneath the space, so RTM is developing many unique routing options for the sanitary piping.


This article originally appeared on RTM Engineering Consultants' blog. RTM Engineering Consultants is a CFE Media Content Partner.

 



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
November 2018
Emergency power requirements, salary survey results, lighting controls, fire pumps, healthcare facilities, and more
October 2018
Approaches to building engineering, 2018 Commissioning Giants, integrated project delivery, improving construction efficiency, an IPD primer, collaborative projects, NFPA 13 sprinkler systems.
September 2018
Power boiler control, Product of the Year, power generation,and integration and interoperability
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me