Project Profile: Ultra-modern CityCenter tower

Aria Tower sits on 68-acres and serves as a centerpiece of the city’s downtown development

09/06/2017


Project name: City Center Aria Tower
Project type: Design-Assist
Engineering firm: Perini Building Company, HKS, Inc
Building type: Hotel
Location: Las Vegas, NV
Timeline: December 1, 2005- December 31 2009

Totaling 62 stories, Aria Tower is one of five high rises and consists of over 4,000 rooms and suites. Courtesy: Southland IndustriesBackground

Located on the Las Vegas strip, the ultra-modern CityCenter Aria Tower sits on 68-acres and serves as a centerpiece of the city’s downtown development with  light shows held against the building’s all-glass facades. Totaling 62 stories, Aria Tower is one of five high rises and consists of over 4,000 rooms and suites distributed across five wings. 

Approach

In order to streamline construction and avoid trade stacking throughout the project, Southland Industries collaborated with the general contractor and subcontractors to develop a short interval project schedule. The design-assist services Southland provided included mechanical and plumbing, as well as building information modeling, coordination, and prefabrication.

The Aria Tower at CityCenter is the world’s largest five star hotel to achieve LEED Gold certification. Courtsey: Southland IndustriesWith a fast track schedule and the need to install work while design was in progress, there was little to no room for errors. The curved shape of the tower became a concern and caused Southland to be creative in the selection of appropriate means and methods to install HVAC and plumbing systems.  To accommodate these needs, Southland rented out an 80,000 square foot fabrication facility and procured all materials, equipment, and fixtures three floors ahead of time. Southland also took the lead with the general contractor in field coordination, allowing minimum rework and fast-paced construction. 

Results

By assisting in the design and construction phase, Southland was able to improve project efficiencies and enhance the overall outcome of installation through prefabrication. The HVAC and plumbing services Southland provided allowed the Aria Tower at CityCenter to become the world’s largest five star hotel to achieve LEED Gold certification.

This article originally appeared on Southland's website. Southland Industries is a CFE content partner. Edited by Hannah Cox, content specialist, CFE Media, hcox@cfemedia.com.



Product of the Year
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
40 Under Forty: Get Recognized
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
MEP Giants Program
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
July 2018
Integrating electrical and HVAC systems, emerging trends in fire, life safety, ASHRAE 90.4
June 2018
Chilled-water system design, NFPA 99, Grounded power supply systems
May 2018
40 Under 40 winners, fire and life safety, performance-based designs, and more
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Data Center Design
Data centers, data closets, edge and cloud computing, co-location facilities, and similar topics are among the fastest-changing in the industry.
click me